Kaohsiung Journal of Medical Sciences
Volume 22, Issue 5 , Pages 223-228, May 2006

A Comparative Study of Three Fecal Occult Blood Tests in Upper Gastrointestinal Bleeding

  • Chien-Hua Chiang

      Affiliations

    • Department of Laboratory Medicine Kaohsiung, Taiwan
  • ,
  • Jen-Eing Jeng

      Affiliations

    • Department of Laboratory Medicine Kaohsiung, Taiwan
  • ,
  • Wen-Ming Wang

      Affiliations

    • Division of Gastroenterology, Department of Internal Medicine, Kaohsiung Medical University Hospital, Kaoshiung Medical University, Kaohsiung, Taiwan
  • ,
  • Bing-Hong Jheng

      Affiliations

    • Department of Laboratory Medicine Kaohsiung, Taiwan
  • ,
  • Wan-Ting Hsu

      Affiliations

    • Department of Laboratory Medicine Kaohsiung, Taiwan
  • ,
  • Bai-Hsiun Chen

      Affiliations

    • Department of Laboratory Medicine Kaohsiung, Taiwan
    • Corresponding Author InformationAddress correspondence and reprint requests to: Dr. Bai-Hsiun Chen, Department of Laboratory Medicine, Kaohsiung Medical University Hospital, 100 Shih-Chuan 1st Road, Kaohsiung 807, Taiwan

Received 20 September 2005; accepted 22 March 2006.

The purpose of this study was to evaluate the performance characteristics of three fecal occult blood tests (FOBTs): the chemical o-toluidine test, the immunochemical OC-Hemodia test, and the immunochromatographic Quick Chaser Occult Blood (QCOB) test, which detect human hemoglobin and transferrin simultaneously in cases of upper gastrointestinal (GI) bleeding. Included were 48 FOBT specimens in 48 consecutive admission cases of upper GI bleeding (endoscopy confirmed). We excluded those fecal specimens with an obvious tarry and bloody appearance. The QCOB test revealed the highest positive rates of 33/48 (68.8%), and significantly higher positive rates than that of the OC-Hemodia test and o-toluidine test (p< 0.025 and < 0.01, respectively). In the patient group with upper GI bleeding due to gastric and duodenal ulcers, the QCOB test had higher positive rates (68.6%) than did the o-toluidine test (34.3%) (p< 0.01). There was no fecal specimen that was positive for the o-toluidine test or OC-Hemodia test and was negative for the QCOB test. Our results reveal that the QCOB test has significantly higher positive rates of fecal occult blood than either the OC-Hemodia test or o-toluidine test. The QCOB test is better than the other two tests for detecting occult blood in patients with upper GI bleeding.

Key Words:  fecal occult blood test , immunochromatography , hemoglobin , transferrin , upper gastrointestinal bleeding

No full text is available. To read the body of this article, please view the PDF online.

 

PII: S1607-551X(09)70240-2

doi:10.1016/S1607-551X(09)70240-2

Kaohsiung Journal of Medical Sciences
Volume 22, Issue 5 , Pages 223-228, May 2006